RVB series

Technical Data

National Standard: JB/T8734.3-2012

Cable Structure

Application

This series of products are suitable for connecting power amplifiers and audio equipment, broadcasting systems to transmit audio signals amplified by power amplifiers or connecting cables for fire fighting appliances.

image.png

Insulation layer: material-high-quality PVC/D; 

Conductor: material-oxygen-free copper.



Product StandardsProduct numberProduct SpecificationsNumber of conductorsConductor diameterAverage thickness of core wireInsulation outer diameterMaximum conductor resistance at 20°CMinimum insulation resistance at 70°C
NmmmmmmΩ/kmMΩ.km
JB/T8734.3-2012(300/300V)RVB2×0.5280.150.882.67×2F390.012
JB/T8734.3-2012(300/300V)RVB2×0.75420.150.882.88×2F260.011
JB/T8734.3-2012(300/300V)RVB2×1.0320.20.883.06×2F19.50.01
JB/T8734.3-2012(300/300V)RVB2×1.5480.20.883.36×2F13.30.01
JB/T8734.3-2012(300/300V)RVB×2.5780.20.883.80×2F7.980.009