ZR-RVS series

Technical Data

National standard: JB/T 8734.3-1998

Cable Structure

Application

This series of products are suitable for fire-fighting appliance connecting wires, household appliances, small power tools, instruments, meters and power lighting wires, etc.

image.png

Insulation layer: material-high-quality PVC/D; 

Conductor: material-oxygen-free copper.



Product StandardsProduct numberProduct SpecificationsNumber of conductorsConductor diameterAverage thickness of core wireMultiples of lay densityMaximum conductor resistance at 20°CMinimum insulation resistance at 70°C
NmmmmΩ/kmMΩ.km
JB/T8734.3-2012(300/300V)ZR-RVS2×0.5280.150 0.88 839.00 0.012 
JB/T8734.3-2012(300/300V)ZR-RVS2×0.75420.150 0.88 826.00 0.011 
JB/T8734.3-2012(300/300V)ZR-RVS2×1.0320.200 0.88 819.50 0.010 
JB/T8734.3-2012(300/300V)ZR-RVS2×1.5480.200 0.88 813.30 0.010 
JB/T8734.3-2012(300/300V)ZR-RVS2×2.5780.200 0.88 87.98 0.009